CO2 Incubators

MCO-170AC-PE IncuSafe CO2 Incubator

Effective capacity
165L
Temperature range
+5℃ above ambient to 50℃

Features

The high-performance solution for mainstream applications

The IncuSafe MCO-170AC CO2 Incubator was developed utilizing advanced technology for unprecedented temperature and CO2 control. Chamber conditions are accurately maintained by the Microprocessor P.I.D controller. The DHA Direct Heat & Air Jacket was designed to surpass the performance of the traditional water jacket and eliminates the inconveniences of using water. Start-up simple and easy with the automatic set-up function.

Copper-enriched Stainless Steel Kills Mycoplasma

PHCbi is proud to announce that InCu saFe, the copper-enriched stainless steel used in the interior of its CO2 and O2/CO2 incubators, kills mycoplasma. Mycoplasma is one of the most common causes of contamination found in cell culture and the source can often be traced back to contaminated laboratory apparatus. The inCu-saFe walls and shelves inside IncuSafe CO2 and O2/CO2 Incubators eliminate mycoplasma and significantly reduce the risk of contamination without emptying the incubator.

PHC Europe B.V. also offers one other size of the same type IncuSafe CO2 Incubator:

Benefits

  • Preventive Contamination Control
  • Ergonomic Design
  • Improved Temperature Stability with D.H.A. System

Features

  • Automatic CO2 Cylinder Switchover System (optional)
  • Ergonomic Design
  • TC Sensor System
  • Double stacking
  • Single chamber
  • Active Background Contamination Control
  • Patented Direct Heat and AIR Jacket Heating System
  • PHCbi inCu saFe copper-alloy-stainless interior, shelves and plenum
  • Field-reversible Door
  • Automatic Gas Cylinder Switchover System (Optional)

Performance

Product Photos

Specifications

External Dimensions (W x D x H) 620 x 730 x 905 mm
Internal Dimensions (W x D x H) 490 x 523 x 665 mm
Volume 165 liters
Net Weight 74 kg
Temperature Control Range & Fluctuation AT +5 ~ +50, ±0.1 °C
Temperature Uniformity ±0.25 °C
CO2 Control Range & Fluctuation 0 ~ 20, ±0.15 %
O2 Control Range & Fluctuation -
Humidity Level & Fluctuation 95, ±5 %RH
Sterilisation Method -
Temperature Sensor Thermistor
CO2 Sensor TC
O2 Sensor -
Display Digital (White graphic Organic LED)
Exterior Material Painted Steel (rear cover not painted)
Interior Material Stainless Steel Copper-Enriched Alloy
Insulation Material Styrene AcryloNitrile copolymer
Heating Method Direct Heat & Air Jacket System
Outer Doors 1
Outer Door Lock Included
Field Reversible Door -
Inner Doors 1 (tempered glass)
Shelves 3 x Stainless Steel Copper-enriched Alloy
Shelf Dimensions (W x D x H) 470 x 450 x 12 mm
Max. Load Per Shelf 7 kg
Max. Shelf Capacity -
Access Port 1
Access Port Position Rear Upper Left
Access Port Diameter 30
Power Failure R
Out of Temperature Setting V-B-R
High Temperature V-B-R
Out of CO2 Setting V-B-R
Out of O2 Setting -
Door Open V
Power Supply 230 V
Frequency 50 Hz
Noise Level 29 dB

Options

SafeCell UV® System MCO-170UVS-PE
CO2 Gas Pressure Regulator MCO-010R-PW
Automatic CO2 Cylinder Changeover system MCO-21GC-PW
Small door MCO-170ID
Incu-saFe® Shelf MCO-170ST-PW
Incu-saFe® Half Tray System MCO-25ST-PW
Double stacking bracket MCO-170PS-PW
Stacking plate MCO-170SB-PW
Roller Base MCO-170RB-PW

Optional communication systems

Analogue interface (4-20mA) MCO-420MA-PW

Dimensions

Downloads